Tips & Tricks: Humidity Level for Electronics Assembly


Reading time ( words)

What is the suggested humidity level for an electronics assembly facility? Do the same limits apply within a 100,000-class cleanroom?

Humidity limits are a combination of ESD control (at the low end) and suitability for use with assembly materials (at both ends).

Low relative humidity (RH) can allow for higher static charges to build on objects. J-STD-001G requires an assessment of the suitability of ESD controls when the RH drops below 30%. This is the primary concern in a cleanroom environment due to the typically higher level of sensitivity of the parts that require cleanroom assembly environments.

Low RH can also affect solder pastes, especially OR-class pastes. Some of the volatile ingredients in the paste formula can be more susceptible to effects from a low RH environment, and this can reduce print performance and stencil life. High RH environments can lead to poor slump resistance of pastes. The range at which pastes are affected by RH will vary based on formulation, so you will need to consult the manufacturer and technical documentation for any paste product.

Jason Fullerton is the customer technical support engineer at the Assembly Division of MacDermid Alpha Electronics Solutions.

Share

Print


Suggested Items

Laserssel Brings High-speed Soldering to New Application Areas

06/10/2019 | Barry Matties, I-Connect007
In this interview with I-Connect007, Denis Barbini, general manager of Laserssel, talks about the company's new laser-selective reflow solution aimed at reducing a typical reflow oven’s 10-minute cycle down to just 10 seconds as well as the overall benefits manufacturers could see from streamlining this process.

Synergy Between Smart Manufacturing and the Secure Supply Chain (Part 2)

06/05/2019 | Michael Ford, Aegis Software Corp.
With the trend of shortening lead-times within the material ordering process, and the frequency with which urgent orders for materials from the grey market are made, there is increased opportunity for the ingress of counterfeit materials. The situation is made far worse when a genuine shortage of materials in the supply chain occurs. The consequences of not being able to eliminate the risk of defects getting through into the market will be disastrous for individuals as well as for the company brand image, not to mention the associated costs of recovery. It is only a matter of time, unless something very significant changes.

The GraftWorx Fluid Management Patch Story

05/31/2019 | Anthony Flannery, GraftWorx
The GraftWorx vision is to connect patients to clinicians with clinical data that will have a meaningful impact on their care. Its first application is to monitor patients with end-stage renal disease or kidney failure using a wearable device called the SmartPatch that records numerous clinical cardiovascular metrics. This article details how GraftWorx was designed, fabricated, and assembled.



Copyright © 2019 I-Connect007. All rights reserved.