-
- News
- Books
Featured Books
- smt007 Magazine
Latest Issues
Current IssueBox Build
One trend is to add box build and final assembly to your product offering. In this issue, we explore the opportunities and risks of adding system assembly to your service portfolio.
IPC APEX EXPO 2024 Pre-show
This month’s issue devotes its pages to a comprehensive preview of the IPC APEX EXPO 2024 event. Whether your role is technical or business, if you're new-to-the-industry or seasoned veteran, you'll find value throughout this program.
Boost Your Sales
Every part of your business can be evaluated as a process, including your sales funnel. Optimizing your selling process requires a coordinated effort between marketing and sales. In this issue, industry experts in marketing and sales offer their best advice on how to boost your sales efforts.
- Articles
- Columns
Search Console
- Links
- Events
||| MENU - smt007 Magazine
Chapter 1 Excerpt: The Printed Circuit Assembler’s Guide to Process Validation
December 31, 2020 | Graham Naisbitt, Gen3 SystemsEstimated reading time: 2 minutes
Quick and Convenient Contamination Testing
The original principle underlying the IPC’s ionic cleanliness requirement was that the mobility of surface ions, detectable from SIR measurements, would correlate to a maximum value of detectable ionic elements permissible on the circuit surface.
The industry required a test that was both fast and accurate for process control. Thus, a simplified ion chromatograph that was able to detect ionic elements without differentiation was created. Due to patent restrictions, there were—and still are—only two different instrument configurations: closed-loop and open-loop, which became referred to as static and dynamic instruments. Each instrument configuration must be capable of measuring the presence of a known amount of ionic contamination.
Based on an extrapolation of insulation resistance measurements, it was determined that there was an upper limit beyond which ionic elements would become mobile on the assembly surface, thereby potentially compromising electrochemical reliability. The number, although occasionally altered during the infancy of this test, was 1.56 µg/cm² NaCl equivalence. Despite the many technology changes employed in the period after the mid-1970s, many—if not most—felt it convenient to simply continue applying this rule as adequate evidence of the electrochemical reliability of their end-product.
The IPC has now withdrawn the requirement for 1.56 µg/cm² NaCl equivalence for a number of reasons as explained in IPC-WP-019A, which states, “For many years, military (e.g., MIL-STD-2000) and commercial (e.g., IPC-J-STD-001) manufacturing standards have required manufactured circuit card assemblies (CCAs) to meet an ionic cleanliness requirement of 1.56 microgram (µg) of sodium chloride (NaCl) equivalence per square centimetre (cm2) of extracted surface, using resistivity of solvent extract (ROSE) testing per IPC-TM-650, method 2.3.25.”
Therefore, it is the position of the IPC committees that the value of 1.56 µg NaCl equivalence per square centimetre should be considered as obsolete for the following seven reasons:
- This test methodology was originally developed in the 1970s. It was never intended to be used as a cleanliness test, nor as a test for product acceptability; it was only intended to be used as a process control method.
- The use of the ionic contamination value as a measure of product acceptance was the result of a U.S. Department of Defense desire to implement pass/fail criteria.
- This ionic contamination value, and those derived from them, were originally developed for high solids (35% solids) rosin fluxes and ozone-depleting chemical (ODC) cleaning. The flux chemistries and cleaning solutions used today are completely different from those used when the ROSE limits were established.
- Modern assemblies are simply too complex in terms of residues to have a single “one-size-fits-all” cleanliness criterion.
- There is mounting evidence that as CCA component density increases, so does the sensitivity of the circuit to ionic contamination. Modern circuit assemblies have far greater component densities than found in the 1970s. This also means that residues that had minimal impact on component technologies from the 1970s can now have a significant impact on component reliability.
- For many assemblies, ROSE testing is no longer a sufficient test regimen to adequately predict acceptable levels of ionic residues. IPC has compiled a list of technical presentations showing the inadequacy of ROSE to predict ionic residues for high-performance electronics.
- It is recognized that ionic residue testing is critical for reliable circuit function, so the ROSE test has continued in use until a more suitable alternative can be identified and implemented.
To download The Printed Circuit Assembler’s Guide to Process Validation, click here. You can also view other titles in our full library.
To view the Gen3 roundtable on the PICT standard, click here.
Suggested Items
I-Connect007 Editor’s Choice: Five Must-Reads for the Week
04/26/2024 | Andy Shaughnessy, Design007 MagazineIn this week’s roundup, we have a variety of articles covering everything from design through assembly, and even box build. I’ve always wondered whether box build was all it was cracked up to be. Do customers really pick one EMS provider over another because one company offers box build? And if you’ve ever wanted to volunteer, IPC’s Thought Leaders Program is looking for a few good technologists to help them on their mission. Check out Stanton Rak’s article, which was published in the spring issue of IPC Community.
Stan Rak: Elevating the Ideas and Insights of IPC's Thought Leaders Program
04/25/2024 | Stanton Rak, SF Rak CompanyAs a member of the IPC Thought Leaders Program (TLP), I am responsible for identifying knowledge-sharing opportunities that can generate ideas and insights that strengthen the IPC community as well as create a sustainable and lasting future for its members. I am delighted to highlight some of my recent contributions as a member of the TLP.
Alternative Manufacturing Inc. Awarded QML Requalification to IPC J-STD-001 and IPC-A-610
04/24/2024 | IPCIPC's Validation Services Program has awarded an IPC J-STD-001 and IPC-A-610 Qualified Manufacturers Listing (QML) requalification to Alternative Manufacturing Inc (AMI).
IPC Design Competition Champion Crowned at IPC APEX EXPO 2024
04/24/2024 | IPCAt IPC APEX EXPO 2024 in Anaheim, California, five competitors squared off to determine who was the best of the best at PCB design.
Big Win for Defense Production Act Budget Allocation in FY24 Budget
04/23/2024 | I-Connect007 Editorial TeamOne year ago, President Biden issued a determination that chips and packaging are critical for national security. Since that time, much work has been done to continue the conversation in Washington, elevating the importance of the entire chips value chain, and including printed circuit boards and substrates, without which chips cannot operate.