- News
- Books
Featured Books
- pcb007 Magazine
Latest Issues
Current IssueThe Hole Truth: Via Integrity in an HDI World
From the drilled hole to registration across multiple sequential lamination cycles, to the quality of your copper plating, via reliability in an HDI world is becoming an ever-greater challenge. This month we look at “The Hole Truth,” from creating the “perfect” via to how you can assure via quality and reliability, the first time, every time.
In Pursuit of Perfection: Defect Reduction
For bare PCB board fabrication, defect reduction is a critical aspect of a company's bottom line profitability. In this issue, we examine how imaging, etching, and plating processes can provide information and insight into reducing defects and increasing yields.
Voices of the Industry
We take the pulse of the PCB industry by sharing insights from leading fabricators and suppliers in this month's issue. We've gathered their thoughts on the new U.S. administration, spending, the war in Ukraine, and their most pressing needs. It’s an eye-opening and enlightening look behind the curtain.
- Articles
- Columns
- Links
- Media kit
||| MENU - pcb007 Magazine
Mr. Laminate Tells All: Where in the Holy Halogens did 900, 900, 1500 Come From?
November 12, 2015 | Doug Sober, Essex Technologies GroupEstimated reading time: 4 minutes

This new column, to appear monthly at PCB007, will focus on base materials and the laminate industry.
The 900, 900, 1500 is not a combination to an enormous safe that contains the remains of Jimmy Hoffa, nor is it the weight of three elephants at the San Diego Zoo in kilograms. The 900, 900, 1500 is the maximum parts per million (ppm) of bromine and chlorine and the total bromine and chlorine in a material that can be defined as “halogen-free” in the electronics industry today. But where did these requirements come from? Clearly, 900 ppm of bromine or chlorine is obviously not halogen-free. Some would argue that it is not even low-halogen at all.
In 2001, during an International Electrotechnical Commission (IEC, Geneva CH) meeting of TC91 Working Group 4: Base Materials and Boards, the member countries decided there should be a specification for FR-4 copper-clad laminates that were halogen-free. Several Japanese manufacturers were selling these laminates and prepregs around the world, primarily in Europe, but there were no specifications to conduct commercial business. Although the square meters per month of sales were quite small at the time, we knew that this product line would grow.
IEC 61249-2-21 was the document number designated in becoming the first FR-4 halogen-free standard in the world. The Working Group 4 decided to base the document and the requirements on the brominated counterpart IEC-61249-2-7 in terms of other property requirements. The main change was a relaxed moisture absorption requirement since halogen-free resins were worse than their brominated counterparts in these tests.
This was the easy part, but defining the halogen content would prove to be more controversial. During subsequent meetings, the Japanese National Committee, led by Dr. Aki Shibata, proposed a maximum of about 450 ppm of chlorine and about 450 ppm of bromine as a specification limit. As the USA National Committee leader, I proposed 1200 ppm for both halogens, as several domestic resin companies presented data that this was a more reasonable number. The debate continued for more than one year. No punches were thrown, but there was still a lot of pain.
One problem was that the copper-clad laminates (CCL), comprised of a higher resin content, generated a higher test value, since all the chlorine and bromine contaminants were coming from the epoxy resin components. For example, a 0.10 or 0.20 mm thick CCL may have a resin content of more than 65% while a 1.52 mm thick CCL may have only 40% resin. So two CCLs using the same resin varnish, but different constructions, generated significantly different results in the halogen test. In the end, the test specimen was defined as eight plies of low resin content/fiberglass fabric construction.
With the test specimen defined, the compromise on the definition of halogen-free between Dr. Shibata and me was decided upon as 900 ppm maximum chlorine, 900 ppm maximum bromine and a new requirement of 1500 ppm maximum for chlorine plus bromine. The rest of the Working Group 4 members agreed to these proposed specifications and the document was completed using the IEC process scheme for developing standards with a vote of the member countries.
Page 1 of 2
Suggested Items
Niche Electronics Announces Major Manufacturing Upgrade
07/08/2025 | Niche ElectronicsNiche Electronics, a leading electronics manufacturing services company, announced today that it has completed installation of Yamaha’s newest SMT lineup at its Pennsylvania production facility.
Hon Hai Reports New June Sales High Amid AI Boom
07/07/2025 | I-Connect007 Editorial TeamTaiwan-based manufacturing giant Hon Hai Precision Industry Co. reported on July 5 that its sales for June rose 10 percent from the previous year, driven by cloud and networking growth because of the boom in artificial intelligence (AI), the Taipei Times reported.
Electronics Industry Wrestles with Cost Pressures and Weaker Profitability
07/07/2025 | Global Electronics AssociationElectronics manufacturers are facing rising material and labor costs according to the Global Electronics Association’s June Sentiment of the Global Electronics Manufacturing Supply Chain Report.
Naprotek Appoints James Eisenhaure as Chief Financial Officer
07/07/2025 | Naprotek LLCNaprotek, LLC, a leading provider of mission-critical electronics technology solutions, today announced that James Eisenhaure has been appointed Chief Financial Officer, effective June 30. Eisenhaure has been serving as interim CFO since earlier this year and now formally steps into the role.
Yannick Green Joins Technica USA as Business Development/Account Manager for Northern California and Northern Nevada
07/07/2025 | Technica USATechnica USA is proud to announce that industry veteran Yannick Green has rejoined Team Technica as Business Development/Account Manager, supporting both supply partners and PCBA customers across Northern California and Northern Nevada.