Blood-flow Sensor for Vascular Disease Monitoring
February 4, 2016 | NIBIBEstimated reading time: 3 minutes
Frequent measurement of blood flow changes could improve the ability of health care providers to diagnose and treat patients with vascular conditions, such as those associated with diabetes and high blood pressure. A U.S.-Chinese team that included researchers from the National Institute of Biomedical Imaging and Bioengineering (NIBIB) and the National Heart, Lung, and Blood Institute, both parts of the National Institutes of Health, conducted a pilot study showing that an ultrathin, skin-conforming sensor—resembling a peel-away tattoo—provides non-invasive, precise, and continuous monitoring of circulation, including blood flow within the smallest vessels.
A sensor that attaches to the skin is used to detect blood flow changes important in monitoring vascular conditions.
In a study published in the Oct. 30, 2015 issue of Science Advances, the researchers showed that the sensor can measure blood flow in both large and micro-sized blood vessels near the skin’s surface. They also provided details about the design and operation of the device. The researchers assessed the sensor’s performance under various conditions, showing that the technology could be used for continuous blood-flow monitoring during daily activities and in a variety of clinical research and health care settings.
In addition to diabetes and chronic hypertension, conditions that affect the health of blood vessels and surrounding tissue include kidney disease, autoimmune and other inflammatory conditions, the effects of aging and smoking, and a class of cholesterol-related abnormalities called dyslipidemias. Continuous monitoring of variations in blood flow could also be valuable in assessing these conditions in clinical and research scenarios.
The pilot-tested device, which was co-developed with researchers at Northwestern University, is among a variety of tools available to measure blood flow. Other devices, such as ones based on optical or acoustic methods, however, do not work as well when the body is in motion, and thus require a patient or study subject to remain still.
The researchers overcame these challenges with the soft, skin-conforming electronic device that is applied directly onto the skin and uses thermal sensors to collect data on changes in temperature, including those caused by changes in blood flow. The device can also apply a small amount of heat in order to test a subject’s responses. In this mode, a miniature pad in the device generates a heat impulse, while 14 surrounding thermal sensors detect the resulting heat flux. The signal is sent to a computer that calculates the velocity of blood flow occurring within two millimeters of the skin surface.
In their study, the researchers placed the sensor on a study subject’s forearm, over a large, visible vein, and then applied pressure for 60 seconds at various positions near the vein. Each time, the device sensed corresponding reductions in blood flow. The researchers also used a thermal camera that measures infrared signals to confirm that the blood-flow sensor measurements were accurate, even when the subject moved around.
Next, they chose a placement on the forearm that was not near a large vein, so that the device would detect blood flow in micro-sized blood vessels within the underlying tissue. The researchers were able to detect changes in blood flow when the study subject took a deep breath. Members of the team at a collaborating institution performed a separate test that involved delivering a gentle slap to the skin near the electronic sensor, which caused a mild reddening reaction. The sensor registered the skin reaction as an increase of surface temperature, accompanied by a change in the direction of blood flow within two millimeters of the skin’s surface.
According to co-author Alexander Gorbach, Ph.D., head of NIBIB’s Infrared Imaging and Thermometry Unit, the tests performed with the thermal sensor helped to establish a number of guidelines for its use, such as optimal placement of the sensor, and how deeply under the skin’s surface the device can assess blood flow. At this stage, the device shows promise as a low-cost, readily-fabricated sensor for use in ambulatory or hospital-based settings. Because of the link between chronic hypertension and some types of vascular diseases, the new sensor may be a useful addition to studies of hypertension and its consequences.
Dr. Gorbach had taken part in prior research, published in 2013, that tested the electronic sensor’s use for collecting continuous body temperature readings. In that study, the team tested the device for use in monitoring the skin temperature of patients under observation for infection or other illnesses. “The clinical standard for temperature readings is two times per day, but this device can send readings two times per second,” he said. In addition, the device can also be used during surgery to monitor the temperature and blood flow of internal organs.
Testimonial
"We’re proud to call I-Connect007 a trusted partner. Their innovative approach and industry insight made our podcast collaboration a success by connecting us with the right audience and delivering real results."
Julia McCaffrey - NCAB GroupSuggested Items
KYZEN to Feature High-Reliability MICRONOX Chemistries at IMAPS Symposium
09/10/2025 | KYZEN'KYZEN, the global leader in innovative environmentally responsible cleaning chemistries, is pleased to announce its participation at the International Symposium on Microelectronics or IMAPS Symposium, taking place September 29-October 3 at Town & Country Resort in San Diego, CA.
MacDermid Alpha Presents at SMTA New Delhi, Bangalore Chapter, on Flux–OSP Interaction
09/09/2025 | MacDermid Alpha Electronics SolutionsMacDermid Alpha contributes technical insights on OSP solderability at the Bangalore Chapter, SMTA reinforcing commitment to knowledge-sharing and industry collaboration.
KYZEN to Highlight High-Reliability MICRONOX Chemistries at SEMICON West 2025
09/08/2025 | KYZEN'KYZEN, the global leader in innovative environmentally responsible cleaning chemistries, is pleased to announce its participation in SEMICON West 2025, taking place October 7–9 at the Phoenix Convention Center in Phoenix, Arizona.
AQUANOX A4618 and CYBERSOLV C8882 to Lead KYZEN Offerings at SMTA Long Island Expo and Tech Forum
08/27/2025 | KYZEN'KYZEN, the global leader in innovative environmentally responsible cleaning chemistries, will exhibit at the SMTA Long Island Expo & Tech Forum on Wednesday, Sept. 10, 2025 at the Marriott Melville Long Island.
Gartner Predicts a $158B Shakeup—ScaleFlux Says the SSD Revolution Has Begun
08/11/2025 | BUSINESS WIREOff-the-shelf SSDs no longer meet the needs of the largest SSD users. Gartner predicts that by 2026, over 30% of on-premises storage will rely on captive NVMe SSDs—up from less than 5% in 2023.