Researchers at the Harvard John A. Paulson School of Engineering and Applied Sciences (SEAS) have developed a dielectric elastomer with a broad range of motion that requires relatively low voltage and no rigid components. This type of actuator could be used in everything from wearable devices to soft grippers, laparoscopic surgical tools, entirely soft robots or artificial muscles in more complex robotics.
Soft robots do a lot of things well but they’re not exactly known for their speed. The artificial muscles that move soft robots, called actuators, tend to rely on hydraulics or pneumatics, which are slow to respond and difficult to store.
Dielectric elastomers, soft materials that have good insulating properties, could offer an alternative to pneumatic actuators but they currently require complex and inefficient circuitry to deliver high voltage as well as rigid components to maintain their form— both of which defeat the purpose of a soft robot.
Now, researchers at the Harvard John A. Paulson School of Engineering and Applied Sciences (SEAS) have developed a dielectric elastomer with a broad range of motion that requires relatively low voltage and no rigid components.
They published their work recently in Advanced Materials.
“We think this has the potential to be the holy grail of soft robotics,” said Mishu Duduta, a graduate student at SEAS and first author of the paper. “Electricity is easy to store and deliver but until now, the electric fields required to power actuators in soft robots has been too high. This research solves a lot of the challenges in soft actuation by reducing actuation voltage and increasing energy density, while eliminating rigid components.”
Duduta co-authored the paper with Robert Wood, the Charles River Professor of Engineering and Applied Sciences and David Clarke, the Extended Tarr Family Professor of Materials.
In building a new dielectric elastomer, the team combined two known materials that worked well individually — an elastomer based on one developed at UCLA that eliminated the need for rigid components and an electrode of carbon nanotubes developed in the Clarke Lab. The complementary properties of these two materials enabled the new device to outperform standard dielectric elastomer actuators.
Most dielectric elastomers have limited range of motion and need to be pre-stretched and attached to a rigid frame. Starting with an elastomer that doesn’t need to be pre-stretched, developed by researchers at UCLA, the modified materials begin as liquids and can be cured rapidly under UV light to produce paper-thin sheets. They are sticky — like double-sided tape — so they can adhere well to each other, and to the electrodes.
For the electrodes, the team replaced carbon grease, which is typically used as an electrode in dielectric elastomers, with a mat of thin carbon nanotubes. The nanotubes neither increase the stiffness of the elastomer nor decrease the energy density — meaning the elastomer can still stretch and provide significant force. The team fabricated the elastomers one on top of the other, creating a multilayer sandwich of elastomer, electrode, elastomer, electrode and so on. In this way, each electrode gets double usage, powering the elastomer above and below.
“The voltage required to actuate dielectric elastomers is directly related to the thickness of the material, so you have to make your dielectric elastomer as thin as possible,” said Duduta. “But really thin elastomers are flimsy and can’t produce force. A multilayer elastomer is much more robust and can actually provide significant force.”
“The significance of this work is that the combination of materials and processing enables two of the current technical limitations of dielectric elastomers — the need for high voltage and pre-stretch — to be overcome,” said Clarke.
This type of actuator could be used in everything from wearable devices to soft grippers, laparoscopic surgical tools, entirely soft robots or artificial muscles in more complex robotics.
“Actuation is one of the most difficult challenges in robotics,” said Wood. “The vast majority of existing robots rely on conventional electromagnetic rotary motors. In cases where we cannot use such motors, for example in soft robots, there are few alternatives for high performance actuation. This breakthrough in electrically-controlled soft actuators brings us much closer to muscle-like performance in an engineered system and opens the door for countless applications in soft robotics.”
Suggested Items
SEMICON Europa 2024 Call for Abstracts Opens
05/21/2024 | SEMISEMI Europe announced the opening of the Call for Abstracts for SEMICON Europa 2024, to be held November 12-15 at Messe München in Munich, Germany. Selected speakers will share their expertise at the Advanced Packaging Conference (APC), Fab Management Forum (FMF), MEMS & Imaging Sensors Summit and during presentations on the show floor.
Material Insight: The Dielectric Constant of PCB Materials
05/17/2024 | Dr. Preeya Kuray -- Column: Material InsightIn the world of PCB design, miniaturization can be achieved by using low dielectric constant (Dk) materials. Low Dk materials can allow for a reduction in thickness while maintaining a given trace width, leading to lower transmission loss and higher density circuitry.
IPC APEX EXPO: Some Thoughts About Growth
05/16/2024 | Dan Feinberg, I-Connect007After two and a half days of wandering the aisles at IPC APEX EXPO 2024, for the first time, I almost felt like I was exploring CES. There were so many booths and exhibits that I could describe, but I’d like to focus on the growth and huge value of this event, which has expanded well beyond just the growing and impressive exhibit show floor.
The Shaughnessy Report: Unlock Your High-speed Material Constraints
05/15/2024 | Andy Shaughnessy -- Column: The Shaughnessy ReportThe world of PCB materials used to be a fairly simple one. It was divided into two groups: the “traditional” laminates, often called FR-4, and the high-speed laminates developed especially for high-speed PCBs. These were two worlds that usually didn’t collide. But then traditional laminates started getting better, and high-speed designers and design engineers took notice and started to reconsider what FR-4 could be used for.
Breaking High-speed Material Constraints: Design007 Magazine — May 2024
05/14/2024 | I-Connect007 Editorial TeamDo you need specialty materials for your high-speed designs? Maybe not. Improvements in resins mean designers of high-speed boards can sometimes use traditional laminate systems instead of high-speed materials, saving time and money while streamlining the fab process. In the May 2024 issue of Design007 Magazine, our contributors explain how to avoid overconstraining your materials when working with high-speed boards.