It’s Time to Retire ROSE Testing
June 27, 2018 | Joe Russeau, Precision Analytical Laboratory, and Mark Northrup, IEC ElectronicsEstimated reading time: 3 minutes

For decades now, the electronics industry has had a growing need to understand the impacts of chemical residues on PCB and PCBA reliability. Residues left from flux and other process chemistries can potentially lead to premature failure of assemblies once in the field. Understanding where such residues originate and their impact on product function is paramount to mitigating product failures due to cleanliness issues. One tool that has been used for decades to evaluate printed board and assembly cleanliness has been the resistivity of solvent extract (ROSE) test.
The ROSE test was developed in the early 1970s by the Naval Avionics Warfare Center in Indianapolis, Indiana. The early test used a squeeze bottle containing a solvent comprised of 75% 2-propanol and 25% deionized water (75/25). The surface of an assembly was rinsed with the 75/25 mixture and any material (e.g., flux) easily soluble in the mixture was dissolved and captured in a beaker. The resistivity of the captured solution was measured, and the result was expressed in terms of sodium chloride equivalents (NaCl eq.). Later versions of the test were automated and a 10.06 microgram (μg) of NaCl eq./in2 (1.56 μg of NaCl eq./cm2) limit was eventually ascribed to the test. That limit became enshrined in various military specifications, such as MIL-P-28809 and WS-6536 and eventually became the industry pass/fail standard. The limit persists today and is used across a wide base of material sets, from bare boards to assemblies to components.
Over the last two to three years, there has been considerable discussion within various IPC committees about the role of the ROSE test in today’s assembly environment. The transition from predominantly water wash processes to “no clean” has meant the advent of very different flux compositions. The question has been posed—on numerous occasions, we might add—as to whether the ROSE test is still a viable option for evaluating PCB and PCBA cleanliness. There have essentially been two camps of thought on the subject: those who want to continue using the test and re-invent it as a process control tool and those that think the test has run its useful course.
To update the test, IPC’s J-STD-001 committee commissioned a subgroup of users and subject matter experts to determine if there was a best-practices use that would bolster its continued application. Two conclusions were reached by that subgroup. First, the ROSE test should no longer be referred to as a cleanliness test, but as a process control tool. This was a reasonable conclusion since ROSE was never meant for cleanliness as industry had defined it. Second, users of the test must provide objective evidence, aside from just ROSE alone, to show that their manufacturing process is in control. More information about what the subgroup defined as “objective” evidence can be found in IPC-WP-019.
The statement made in the title to this article is where we want to focus most of our discussion. We are in the camp that believes the ROSE test provides little value for evaluating today’s assembly products and here’s why. The first significant concern with the validity of the ROSE test is the solvent. Back when the test was developed the predominant flux being used was heavily comprised of rosin (>30%). The 75/25 mixture was a very effective solvent for breaking down that flux and bringing it into solution. This is an important factor to consider because to accurately measure the amount of residual flux on a PCBA, you must first have a solvent that can dissolve it into solution. This is one of the major problems with the ROSE test today.
Why is the solvent an important consideration? Typically, four questions that are asked when performing cleanliness testing of assemblies. The questions are as follows:
1. What types of residues are on the surface of the assembly?
2. What are the concentrations of those residues?
3. Do those residues/concentrations pose any risk to product performance/function?
4. Where are the residues originating?
To have any hope of answering these questions, we need to consider a testing platform with two very specific attributes: selectivity and sensitivity. With the advances in board design, product miniaturization, process improvement and the myriad of chemicals used in assembly production today, a bulk-solvent measurement is not adequate for determining if there are any hidden residue traps.
To read the full version of this article, which appeared in the in the May 2018 issue of SMT007 Magazine, click here.
Suggested Items
Real Time with... IPC APEX EXPO 2025: Empowering IPC North Asia—Leadership and Future Goals
04/24/2025 | Real Time with...IPC APEX EXPONolan Johnson catches up with Sydney Xiao, the IPC North Asia President, who leads a team covering China, Taiwan, Japan, and Korea. IPC's North Asia regions 800 members are focusing on standards, training, and advocacy to enhance quality and profitability. The adoption of IPC standards by Toyota in 2021 highlights this increased regional engagement. IPC prioritizes workforce development, with over 7,000 professionals in certification programs and school partnerships.
Recognizing the IPC Committee Volunteer Awards in 2025
04/24/2025 | Patty Goldman, I-Connect007In 2023, IPC created two new awards to honor standards development committee volunteers: The Hillman-Lambert Award for Volunteer of the Year and the Kessler-Goldman Award for Committee Leader of the Year. The awards were named after Hall of Fame members whose service to standards development is well-known and who have demonstrated the skills and principles that the awardees should also have.
IPC Rising Star Award: Young-Ho Hwang, Guru E&E
04/23/2025 | Nolan Johnson, I-Connect007Since 2022, IPC has made significant progress for its Korean members. Young-Ho Hwang has been instrumental in driving these developments. As a core advisory committee member and chair of the 610 RTG, he has played a key role in guiding IPC Korea’s strategic direction, championed the development and adoption of IPC standards across industries, and fostered strong collaborations with stakeholders.
Real Time with... IPC APEX EXPO 2025: IPC's Growth and Future in India's Manufacturing Sector
04/23/2025 | Real Time with...IPC APEX EXPOGaurab Majumdar, VP for IPC in SE Asia and India, highlights IPC's impressive growth in India, with certification numbers rising significantly. The Indian manufacturing sector is projected to reach a $300 billion market, alongside a $10 billion investment in semiconductors. IPC is addressing industry demands through standards development and a new workforce project aimed at training students for job placements.
Real Time with... IPC APEX EXPO 2025: DuPont Electronics Materials and Innovations
04/23/2025 | Real Time with...IPC APEX EXPODuPont is many things to many markets, but DuPont Electronics Materials is, perhaps, a bit out of the DuPont "norm," developing specialized electronic materials that are particularly focused on challenging areas such as flex circuits, high power PCBs and products that must withstand harsh environments. At IPC APEX EXPO, Marcy LaRont sat down with Shannon Dugan from DuPont Electronics Materials to discuss some big news. They are being spun off into an independent entity with a new CEO having just been announced as the show wrapped.