New Ultrasound-Powered Actuator to Power Micro Robot
November 23, 2016 | AMERICAN INSTITUTE OF PHYSICSEstimated reading time: 1 minute
The quest to develop a wireless micro-robot for biomedical applications requires a small-scale "motor" that can be wirelessly powered through biological media. While magnetic fields can be used to power small robots wirelessly, they do not provide selectivity since all actuators (the components controlling motion) under the same magnetic field just follow the same motion. To address this intrinsic limitation of magnetic actuation, a team of German researchers has developed a way to use microbubbles to provide the specificity needed to power micro-robots for biomedical applications.
This week in Applied Physics Letters ("A portable paper-based microfluidic platform for multiplexed electrochemical detection of human immunodeficiency virus and hepatitis C virus antibodies in serum"), the team describes this new approach that offers multiple advantages over previous techniques.
"First, by applying ultrasound at different frequencies, multiple actuators can be individually addressed; second, the actuators require no on-board electronics which make them smaller, lighter and safer; and third, the approach is scalable to the sub-millimeter size," said Tian Qiu, a researcher at the Max Planck Institute for Intelligent Systems in Germany.
The research team encountered some surprises along the way. Normally a special material, like a magnetic or piezoelectric material, is required for an actuator. In this case, they used a standard commercial polymer that simply traps air bubbles, and then used the air-liquid interface of the trapped bubbles to convert the ultrasound power into mechanical motion.
"We found that a thin surface (30-120 micrometers effective thickness) with appropriate topological patterning can provide propulsion force using ultrasound, and thousands of these bubbles together can push a device at millimeter scale," Qiu said. "The simplicity of the structure and material to accomplish this task was a pleasant surprise."
The team is already looking forward to developing their actuator further.
"The next steps are to increase the propulsive force of the functional surface, to integrate the actuator into a useful biomedical device, and then to test it in a real biological environment, including in vivo," Qiu said.
The adoption of micro-structured surfaces as wireless actuators opens promising new possibilities in the development of miniaturized devices and tools for fluidic environments accessible by low intensity ultrasound fields. These functional surfaces could serve as ready-to-attach wireless actuators, powering miniaturized biomedical devices for applications such as active endoscopes.
Testimonial
"Advertising in PCB007 Magazine has been a great way to showcase our bare board testers to the right audience. The I-Connect007 team makes the process smooth and professional. We’re proud to be featured in such a trusted publication."
Klaus Koziol - atgSuggested Items
U.S. Uses Secret Trackers to Trace AI Chips Diverted to China, Sources Say
08/18/2025 | I-Connect007 Editorial TeamTwo sources told Reuters that U.S. authorities have secretly placed location trackers in some advanced chip shipments they see as at high risk of illegal diversion to China. They said the trackers are intended to locate AI chips that are sent to locations restricted by U.S. export laws, but authorities only examine some shipments.
Happy’s Tech Talk #38: Novel Metallization for UHDI
05/07/2025 | Happy Holden -- Column: Happy’s Tech TalkI have been involved in high-density electronics substrates since 1970 when I joined Hewlett-Packard’s RF semiconductor group after college. Figure 1 shows the difference between trace/space lithography for substrates and silicon starting in 1970. My projects involved sapphire circuits for RF devices, but the figure displays the state of PCBs and integrated CMOS circuits and their packaging, not discreet RF devices. Even then, semiconductors were 50X higher density.
New Database of Materials Accelerates Electronics Innovation
05/05/2025 | ACN NewswireIn a collaboration between Murata Manufacturing Co., Ltd., and the National Institute for Materials Science (NIMS), researchers have built a comprehensive new database of dielectric material properties curated from thousands of scientific papers.
New Database of Materials Accelerates Electronics Innovation
05/02/2025 | ACN NewswireIn a collaboration between Murata Manufacturing Co., Ltd., and the National Institute for Materials Science (NIMS), researchers have built a comprehensive new database of dielectric material properties curated from thousands of scientific papers.
Micron Announces Business Unit Reorganization to Capitalize on AI Growth Across All Market Segments
04/23/2025 | MicronMicron Technology, Inc., a leader in innovative memory and storage solutions, announced a market segment-based reorganization of its business units to capitalize on the transformative growth driven by AI, from data centers to edge devices.