Biodegradable Sensor Monitors Pressure in the Body then Disappears
January 18, 2018 | University of ConnecticutEstimated reading time: 4 minutes
UConn engineers have created a biodegradable pressure sensor that could help doctors monitor chronic lung disease, swelling of the brain, and other medical conditions before dissolving harmlessly in a patient’s body.
The UConn research is featured in the current online issue of the Proceedings of the National Academy of Sciences.
The small, flexible sensor is made of medically safe materials already approved by the U.S. Food and Drug Administration for use in surgical sutures, bone grafts, and medical implants. It is designed to replace existing implantable pressure sensors that have potentially toxic components.
Those sensors must be removed after use, subjecting patients to an additional invasive procedure, extending their recovery time, and increasing the risk of infection.
Because the UConn sensor emits a small electrical charge when pressure is applied against it, the device also could be used to provide electrical stimulation for tissue regeneration, researchers say. Other potential applications include monitoring patients with glaucoma, heart disease, and bladder cancer.
“We are very excited because this is the first time these biocompatible materials have been used in this way,” says Thanh Duc Nguyen, the paper’s senior author and an assistant professor of mechanical and biomedical engineering in the Institute of Regenerative Engineering at UConn Health and the Institute of Materials Science at the Storrs campus.
“Medical sensors are often implanted directly into soft tissues and organs,” Nguyen notes. “Taking them out can cause additional damage. We knew that if we could develop a sensor that didn’t require surgery to take it out, that would be really significant.”
A prototype sensor made by the lab consisted of a thin polymer film five millimeters long, five millimeters wide, and 200 micrometers thick. The sensor was implanted in the abdomen of a mouse in order to monitor the mouse’s respiratory rate. It emitted reliable readings of contractions in the mouse’s diaphragm for four days before breaking down into its individual organic components.
To make sure the sensor was also medically safe, the researchers implanted it in the back of a mouse and then watched for a response from the mouse’s immune system. The results showed only minor inflammation after the sensor was inserted, and the surrounding tissue returned to normal after four weeks.
One of the project’s biggest challenges was getting the biodegradable material to produce an electrical charge when it was subjected to pressure or squeezed, a process known as the piezoelectric effect. In its usual state, the medically safe polymer used for the sensor – a product known as Poly(L-lactide) or PLLA – is neutral and doesn’t emit an electrical charge under pressure.
Eli Curry, a graduate student in Nguyen’s lab and the paper’s lead author, provided the project’s key breakthrough when he successfully transformed the PLLA into a piezoelectric material by carefully heating it, stretching it, and cutting it at just the right angle so that its internal molecular structure was altered and it adopted piezoelectric properties. Curry then connected the sensor to electronic circuits so the material’s force-sensing capabilities could be tested.
When put together, the UConn sensor is made of two layers of piezoelectric PLLA film sandwiched between tiny molybdenum electrodes and then encapsulated with layers of polylactic acid or PLA, a biodegradable product commonly used for bone screws and tissue scaffolds. Molybdenum is used for cardiovascular stents and hip implants.
The piezoelectric PLLA film emits a small electrical charge when even the most minute pressure is applied against it. Those small electrical signals can be captured and transmitted to another device for review by a doctor.
As part of their proof of concept test for the new sensor, the research team hardwired an implanted sensor to a signal amplifier placed outside of a mouse’s body. The amplifier then transmitted the enhanced electrical signals to an oscilloscope where the sensor’s readings could be easily viewed.
The sensor’s readings during testing were equal to those of existing commercial devices and just as reliable, the researchers say. The new sensor is capable of capturing a wide range of physiological pressures, such as those found in the brain, behind the eye, and in the abdomen.
The sensor’s sensitivity can be adjusted by changing the number of layers of PLLA used and other factors.
Nguyen’s group is investigating ways to extend the sensor’s functional lifetime. The lab’s ultimate goal is to develop a sensor system that is completely biodegradable within the human body.
But until then, the new sensor can be used in its current form to help patients avoid invasive removal surgery, the researchers say.
“There are many applications for this sensor,” says Nguyen. “Let’s say the sensor is implanted in the brain. We can use biodegradable wires and put the accompanying non-degradable electronics far away from the delicate brain tissue, such as under the skin behind the ear, similar to a cochlear implant. Then it would just require a minor treatment to remove the electronics without worrying about the sensor being in direct contact with soft brain tissue.”
Nguyen’s research group has filed for a patent for the new sensor. The patent application is pending.
The other authors on the paper are: Kai Ke, Kinga Wrobel, Albert Miller III, and Avi Patel from the Nguyen Research Group; Dr. Cato Laurencin, Dr. Qian Wu, Lixia Yue, Kevin Lo, Insoo Kim, Chia-Ling Kuo, and Jianling Feng from UConn Health; and Professor Horea Ilies and Meysam Chorsi from UConn’s Computational Design Lab. Associate professor Prashant Purohit from the University of Pennsylvannia also contributed.
Suggested Items
Happy’s Tech Talk #34: Producibility and Other Pseudo-metrics
11/12/2024 | Happy Holden -- Column: Happy’s Tech TalkAs an engineer, I thrive on data, and one of my favorite forms is metrics. However, the one metric that has always challenged me is producibility. I define this as more than just passing a DRC in CAM, but the entire envelope of “simplicity of design,” “suitability for test,” and many more. Yet, producibility seemed to be different for different engineers and we had no clear way to establish and define producibility other than opinion. When I worked at HP, the company invested in a methodology called design for manufacturing and assembly using the GE/Hitachi Methodology and Dewhurst-Boothroyd software. Finally, I had a methodology that created a producibility score.
Flexible Thinking: Musings on High Density Interconnections
10/30/2024 | Joe Fjelstad -- Column: Flexible ThinkingPeople have been using high density interconnection (HDI) technology since the early 1980s, although it was not called HDI until the late 1990s. In the 1970s, ’80s, and early ’90s, engineers used HDI methods to develop hybrid circuits, which were later referred to as multichip modules (MCMs). These were arguably the first instantiation of heterogeneous interconnection technology, which has been the industry buzzword for almost a decade. These devices are a way of integrating multiple chips—both integrated circuits and discrete devices (resistors, capacitors, and inductors)—into a single package, typically using ceramic substrates with layers of insulation and metallic inks (often gold) and firing them at high temperatures.
It’s Only Common Sense: Want to Succeed? Stay in Your Lane
10/28/2024 | Dan Beaulieu -- Column: It's Only Common SenseIn today’s busy world, there are so many things going on, that it’s easy to get distracted. We live in an era of constant comparison and nonstop disruption. Everyone’s talking about the latest technology, the economy’s twists and turns, globalization, or how Company X is doing something you’re not. But here’s the thing: None of that matters if you’re not focused on your path. I’m going to say it straight: Stay in your lane. It’s the only way you’ll ever find success in business and life.
Book Excerpt: The Printed Circuit Designer’s Guide to... DFM Essentials, Ch. 1
10/25/2024 | I-Connect007The guidelines offered in this book are based on both ASC recommendations and IPC standards with the understanding that some may require adjustment based on the material set, fabricator processes, and other design constraints. This chapter details high-frequency materials, copper foil types, metal core PCBs, and the benefits of embedded capacitance and resistor materials in multilayer PCBs.
The Cost-Benefit Analysis of Direct Metallization
10/21/2024 | Carmichael Gugliotti, MacDermid AlphaCarmichael Gugliotti of MacDermid Alpha discusses the innovative realm of direct metallization technology, its numerous applications, and significant advantages over traditional processes. Carmichael offers an in-depth look at how direct metallization, through developments such as Blackhole and Shadow, is revolutionizing PCB manufacturing by enhancing efficiency, sustainability, and cost-effectiveness. From its origins in the 1980s to its application in cutting-edge, high-density interconnects and its pivotal role in sustainability, this discussion sheds light on how direct metallization shapes the future of PCB manufacturing across various industries, including automotive, consumer electronics, and beyond.