- News
- Books
Featured Books
- pcb007 Magazine
Latest Issues
Current IssueThe Growing Industry
In this issue of PCB007 Magazine, we talk with leading economic experts, advocacy specialists in Washington, D.C., and PCB company leadership to get a well-rounded picture of what’s happening in the industry today. Don’t miss it.
The Sustainability Issue
Sustainability is one of the most widely used terms in business today, especially for electronics and manufacturing but what does it mean to you? We explore the environmental, business, and economic impacts.
The Fabricator’s Guide to IPC APEX EXPO
This issue previews many of the important events taking place at this year's show and highlights some changes and opportunities. So, buckle up. We are counting down to IPC APEX EXPO 2024.
- Articles
- Columns
Search Console
- Links
- Events
||| MENU - pcb007 Magazine
Using the Type 1 Gauge Study to Assess Measurement Capability
July 26, 2016 | Patrick Valentine, UYEMURA USAEstimated reading time: 1 minute
Measurement capability is a critical aspect of ensuring product quality, therefore a measurement system must be assessed before being used on products. Understanding how to assess measurement capability becomes critical. The Type 1 Gauge study is typically the first step in a measurement system analysis program. Type 1 Gauge parameters are explained, and a worked example using electroless nickel immersion gold (ENIG) is provided.
What Does the Type 1 Gauge Study Do? There are two major types of measurement system variation:
1. Accuracy is variation between the measurement and a true or reference value
2. Precision is variation between repeated measurements
A Type 1 Gauge study involves repeated measurements of one sample by one gauge and by one operator. With this information, the
Type 1 Gauge study provides an assessment of the following:
1. Accuracy, assuming a reference value is available
2. Precision of repeated measurements
Without an accepted reference value, the Type 1 Gauge study only measures precision, and accuracy becomes unavailable. Bias is a quantitative term used to describe accuracy. Bias is the difference between the average of measurements made on the reference value and its true value.
A Type 1 Gauge study considers only the inherent variation of the gauge itself. A Type 1 Gauge study isolates the effects of accuracy and precision, and evaluates the capability of the gauge to make accurate measurements with acceptable variability. A Type 1 Gauge study does not assess operator-to-operator or gaugeto-gauge variation. A more complex gauge repeatability and reproducibility (R&R) study is indicated for a more comprehensive measurement system analysis.
To read this entire article, which appeared in the July 2016 issue of The PCB Magazine, click here.
Suggested Items
I-Connect007 Editor’s Choice: Five Must-Reads for the Week
05/03/2024 | Nolan Johnson, I-Connect007This week’s most important news is strategic—and telling. When one puts together the IPC industry reports, we simply have to include the recent conversation with Shawn DuBravac and Tom Kastner. On the design side, check out the latest “On The Line With…” podcast featuring Brad Griffin from Cadence Design Systems, discussing SI and PI in the realm of intelligent system design.
Industrial PC Market Size to Record $1.75 Billion Growth from 2023-2027
05/03/2024 | PRNewswireThe global industrial pc market size is estimated to grow by USD 1.75 billion from 2023 to 2027, according to Technavio. This growth is expected to occur at a Compound Annual Growth Rate (CAGR) of almost 6.29% during the forecast period.
Real Time with… IPC APEX EXPO 2024: Sigma Engineering's Recycling and Regeneration Systems for PCB Etching
05/02/2024 | Real Time with...IPC APEX EXPOEvan Howard of Schmoll America interviews Kristoffer Bjorklund, Sigma Engineering's supply chain manager. We learn about Sigma's recycling and regeneration systems for PCB industry etching and the benefits and challenges of implementing these systems in existing factories.
Boeing T-7A Red Hawk Triples Progress
05/01/2024 | BoeingThe Boeing T-7A Red Hawk achieved three recent milestones, propelling the advanced pilot trainer for the U.S. Air Force forward.
Merlin Flex invests in New Schmoll Direct Imaging System
04/30/2024 | Merlin Flex LtdMerlin Flex has fully installed and commissioned its 2nd Schmoll MDI Direct Imaging system. This new machine includes a twin bed, 4 head system which enhances Merlin Flex’s direct imaging capability for its 1.4M long flexible circuits.