-
- News
- Books
Featured Books
- pcb007 Magazine
Latest Issues
Current IssueAdvancing the Advanced Materials Discussion
Moore’s Law is no more, and the advanced material solutions to grapple with this reality are surprising, stunning, and perhaps a bit daunting. Buckle up for a dive into advanced materials and a glimpse into the next chapters of electronics manufacturing.
Inventing the Future With SEL
Two years after launching its state-of-the-art PCB facility, SEL shares lessons in vision, execution, and innovation, plus insights from industry icons and technology leaders shaping the future of PCB fabrication.
Sales: From Pitch to PO
From the first cold call to finally receiving that first purchase order, the July PCB007 Magazine breaks down some critical parts of the sales stack. To up your sales game, read on!
- Articles
- Columns
- Links
- Media kit
||| MENU - pcb007 Magazine
Estimated reading time: 1 minute

Testing Todd: How are the Ratings?
Hello, readers! Thank you for stopping by again. Let’s talk about ratings. No, I’m not talking about the latest Facebook likes or Twitter retweets, but a topic that confuses many final QA technicians the world over. I’m talking PCB voltage ratings.
If you are an electrical test engineer/technician, I’m sure you have seen many master drawings that use the term “Maximum Rated Voltage is XXX Volts,” where XXX is a number.
I have seen many final inspection areas that will reject a final ET certificate of compliance (CoC) because they read the master drawing and see a statement such as “maximum rated voltage = 24V” but the CoC says it was tested at 250 volts! The manufacturing specification is also stated as IPC-6012D(DS). Is the CoC wrong? In most cases, no. “Todd, can this be?” you ask. Well, in this case, it is correct.
Master drawings carry a gambit of information for the manufacture of printed circuits. Many notations are specific instructions and call-outs for the PWB. However, there are many “statements” on the master drawing as well. The term “maximum rated voltage” is one of those statements. In many cases, when you read that statement, you can think, “Thank you for that. Good to know.” Does that mean that I have to test that PWB at the rated voltage? In many cases the answer is no.
What that statement is telling you is that in that PCB’s duty cycle (life) it will never see a voltage higher than what is stated. Again, good to know, right?
To read the full version of this article which appeared in the April 2018 issue of PCB007 Magazine, click here.
More Columns from Testing Todd
Testing Todd: Why 4-wire Kelvin?Testing Todd: Why TDR?
Testing Todd: Positivity Boosts Employee Morale
Testing Todd: Preparing Employees for the Long Haul
Testing Todd: Where Can We Improve?
Testing Todd: Turning Into the Wind
Testing Todd: Coming Back to Life—Design Recovery
Testing Todd: Decision Time—Invest or Delegate?