New Route to Thermal Measurements with Nanometer Resolution
March 3, 2016 | CCNYEstimated reading time: 2 minutes
Understanding nanoscale heat flow is critical in the design of integrated electronic devices and in the development of materials for thermal insulation and thermoelectric energy recovery. While several techniques are currently available to observe heat transport over macroscopic distances, there is a need for new methods capable of revealing the dynamics of heat flow with nanometer resolution.
A team led by Physics Professors Carlos Meriles of CCNY and Elisa Riedo of the CUNY Advanced Science Research Center's Nanoscience Initiative report on a versatile platform for nanoscale thermal measurements based on a combination of magnetic resonance, and optical and atomic force microscopy, in Nature Communications. Their paper, “Imaging thermal conductivity with nanoscale resolution using a scanning spin probe,” is based on a simple notion: that a hot probe in contact with a thermally conductive material, such as a metal, cools down because heat flows from the probe into the material. The latter is prevented, however, if the sample material is thermally insulating, implying that one can infer the sample thermal conductivity by continuously monitoring the probe temperature.
To implement this idea at the nanoscale, the researchers used a thermal atomic force microscope, where the cantilever temperature can be adjusted via the application of an external current. The AFM cantilever hosts a sharp tip that makes contact with the substrate on a small, nanometer-size area. To measure the tip temperature, the CCNY team attached to the tip apex a diamond nanocrystal, whose thermally-dependent fluorescence effectively made it a tiny thermometer. Nanometer-resolved thermal conductivity maps were then obtained as the tip was scanned over various substrates of heterogeneous composition.
The team anticipates multiple applications ranging from fundamental problems of heat flow in nanostructures and radiative heat transport in nano-gaps, to the characterization of materials undergoing heterogeneous phase transitions, to the investigation of catalytic exothermal reactions. Although in the present implementation heat flows from the AFM tip into the sample, the technique can be immediately adapted to probe the local temperature in a hot, non-uniform substrate without the need of a thermal cantilever.
“This form of nanoscale scanning thermometry can play an important role in the characterization of the ‘hot spots’ formed at the junctions of semiconductor heterostructures, known to be critical in the generation of heat within integrated electronic devices,” said Meriles.
About The City College of New York
Since 1847, The City College of New York has provided low-cost, high-quality education for New Yorkers in a wide variety of disciplines. More than 16,000 students pursue undergraduate and graduate degrees in: the College of Liberal Arts and Sciences; the Bernard and Anne Spitzer School of Architecture; the School of Education; the Grove School of Engineering; the Sophie Davis School of Biomedical Education, and the Colin Powell School for Civic and Global Leadership. U.S. News, Princeton Review and Forbes all rank City College among the best colleges and universities in the United States.
Suggested Items
I-Connect007’s Editor’s Choice: Five Must-Reads for the Week
07/04/2025 | Marcy LaRont, I-Connect007For our industry, we have seen several bullish market announcements over the past few weeks, including one this week by IDC on the massive growth in the global server market. We’re also closely watching global trade and nearshoring. One good example of successful nearshoring is Rehm Thermal Systems, which celebrates its 10th anniversary in Mexico and the official opening of its new building in Guadalajara.
Driving Innovation: Direct Imaging vs. Conventional Exposure
07/01/2025 | Simon Khesin -- Column: Driving InnovationMy first camera used Kodak film. I even experimented with developing photos in the bathroom, though I usually dropped the film off at a Kodak center and received the prints two weeks later, only to discover that some images were out of focus or poorly framed. Today, every smartphone contains a high-quality camera capable of producing stunning images instantly.
United Electronics Corporation Advances Manufacturing Capabilities with Schmoll MDI-ST Imaging Equipment
06/24/2025 | United Electronics CorporationUnited Electronics Corporation has successfully installed the advanced Schmoll MDI-ST (XL) imaging equipment at their advanced printed circuit board facility. This significant technology investment represents a continued commitment to delivering superior products and maintaining their position as an industry leader in precision PCB manufacturing.
Orbel Corporation Integrates Schmoll Direct Imaging
06/04/2025 | Schmoll AmericaOrbel Corporation in Easton, PA, proudly becomes the first PCM facility in the U.S. equipped with Schmoll’s MDI Direct Imaging system. This installation empowers Orbel to support customers with greater precision and quality.
Key Insights on Photoresist for Defect Reduction
05/21/2025 | I-Connect007 Editorial TeamIn PCB manufacturing, understanding the intricacies of the photoresist process is crucial for achieving high-quality results. Industry experts Josh Krick, a technical service engineer at IEC, and Tim Blair, a PCB imaging specialist at Tim Blair LLC, share their knowledge on the essential stages of photoresist application, highlight critical advancements in materials, and discuss common defects encountered during production. They share best practices and innovative solutions to enhance the manufacturing process, reduce defects, and ensure efficiency and reliability in high-tech applications.